Universal Safety Systems delivered over 1,600 SkyAngel rooflight protection covers for a commercial development ahead of solar panel installation. Completed within approximately one month, the project required protection for fragile rooflights that would retain natural daylight and support future rooftop maintenance.
The project demonstrates how planning skylight protection before solar installation can help manage fall-through hazards and coordinate protection with the wider construction programme.
Project Overview
| Project Detail | Summary |
|---|---|
| Project Scale | Over 1,600 SkyAngel rooflight covers |
| Application | Rooflight protection ahead of commercial solar panel installation |
| Main Requirements | Fall-through protection, continued daylight transmission and protection for future maintenance |
| Installation Programme | Approximately one month |
| Delivery Approach | Staged deliveries coordinated with the installation programme |
The challenge: rooflight protection around a planned solar installation
The development incorporated more than 1,600 rooflights across roof areas where photovoltaic arrays were due to be installed.
Rooflights provide valuable natural daylight, but fragile rooflights present a fall-through hazard during construction and maintenance. Brining solar installation teams onto the roof made it important to address this hazard before work began.
The project required a skylight protection system that could meet three practical needs:
- Protect fragile rooflights during solar panel installation
- Allow natural light to continue entering the building
- Provide ongoing protection when teams returned for maintenance
With so many rooflights involved, the solution also needed to support a coordinated installation programme without creating unnecessary delivery or storage difficulties.
Why SkyAngel skylight protection covers were selected
SkyAngel creates a physical barrier above a fragile rooflight, providing fall-through protection while allowing daylight to pass through its open mesh construction.
For this deployment, the system combined rooflight protection with a low-profile design suited to a roof accommodating solar arrays. Its mesh construction retained the rooflights’ daylight function, while the cover system provided protection for subsequent maintenance activities.
These external skylight covers serve a safety purpose: they protect fragile rooflight areas rather than providing blackout or shading.
| System Specification or Characteristic | Project Benefit | |
|---|---|---|---|
| Fall-through protection | Physical barrier positioned above the fragile rooflight | Protects the rooflight area during installation and future maintenance activities | |
| Mesh construction | Galfan-coating steel mesh | Provides impact resistance and corrosion resistance for external use | |
| Frame construction | Rigid PVC-U frame | Supports the protective mesh above the rooflight | |
| Daylight transmission | Open mesh design allows natural daylight to pass through | Detains the rooflights’ lighting function | |
| Profile | Low-profile cover design | Supports integration with the surrounding rooftop layout | |
| Rooflight suitability | Configurations available for different rooflight dimensions and shapes | Allows the system to be specified for the rooflights being protected |
The cover configuration and installation requirements should follow the relevant SkyAngel instructions and project specification.
Coordinating more than 1,600 rooflight covers
At this scale, supplying the covers was only one part of the challenge. Materials needed to reach the installation teams in step with the programme.
USS coordinated staged deliveries to reduce on-site storage requirements while maintaining access to the covers needed for each installation phase. Production planning and technical support helped coordinate the order with the project timetable.
This approach connected supply, delivery and installation rather than treating them as separate activities.
The programme combined installation sequencing with checks on cover positioning and secure fixing. USS worked with the project team to establish verification procedures across the installation, supporting consistency over a large number of rooflights.
Technical assistance remained available throughout the installation period. This helped the teams address installation requirements while maintaining progress.
Project outcomes
| Outcome | Recorded Project Result |
|---|---|
| Rooflight Protection | Over 1,600 SkyAngel covers installed |
| Installation Duration | Approximately one month |
| Delivery Performance | Deliveries coordinated with the installation schedule |
| Product Quality | No defects reported across the supplied units |
| Continued Customer Relationship | A further order placed within weeks of completion |
The completed installation provided protection ahead of the solar works while allowing daylight to continue entering the building.
The subsequent order provided further evidence of customer confidence in the solution and delivery process.
Solar panel skylight protection beyond installation
Roof access requirements continue after solar panels are installed. Inspections, cleaning, repairs and other maintenance can bring operatives back into proximity with fragile rooflights.
Planning solar panel skylight protection at the outset allows rooflight covers to be considered alongside the array layout and future access routes. It also helps avoid treating rooflight safety as a separate issue once the installation is complete.
For this project, the SkyAngel covers provided ongoing protection around the rooflights. Their continued performance depends on appropriate inspection, maintenance and use in accordance with the system requirements.
What this project demonstrates
The project highlights three considerations for facilities managers, contractors and building owners planning similar work.
Address rooflight hazards before solar work begins
Identify fragile rooflights early and include their protection in the rooftop work plan. This allows the protection strategy to be coordinated with the solar installation programme.
Consider daylight as well as protection
A rooflight protection solution should account for the rooflight’s function. Open mesh skylight covers provide a protective barrier while allowing natural light to reach the spaces below.
Plan for future maintenance access
Consider how people will reach and maintain the solar installation throughout its operational life. Rooflight protection should be assessed alongside access routes, roof edges and other hazards.
HSE guidance on fragile surfaces explains the need to avoid work on or near fragile surfaces where possible and control the remaining risks.
Questions about skylight and rooflight protection covers
What should you consider when choosing a skylight cover?
Consider the rooflight’s dimensions, shape and condition, the surrounding roof construction, and the work that will take place nearby. For solar projects, the proposed array layout and future maintenance routes should also inform the specification.
Can rooflight covers be used alongside solar panels?
Rooflight protection covers can form part of a roof safety strategy for buildings with solar installations. Their positioning should be coordinated with the solar equipment and access arrangements so the rooflights remain protected and maintenance routes are properly considered.
Are rooflight covers the same as roof walkways?
They have different functions. Rooflight covers provide protection over fragile rooflights, while walkways establish access routes across the roof. Do not assume a cove is a designated walking or working platform; follow the system’s approved use.
Do skylight protection covers remove the need for other fall protection?
Rooflight covers address the fall-through hazard at the protected rooflight. Roof edges, other fragile surfaces and access risks still need assessment. The wider safety solution may require guardrails, walkways or personal fall protection, depending on the work and roof layout.
Planning rooflight protection for a commercial solar project?
This project shows how more than 1,600 rooflights could be protected within a coordinated installation programme, with daylight and future maintenance requirements considered from the outset.
Explore SkyAngel skylight and rooflight protection covers or contact Universal Safety Systems to discuss your rooflight dimensions, roof construction and planned rooftop work.
Related Resources