01299 250155 [email protected] Mon–Thur: 08:30–17:00 | Fri: 08.30–16.00
01299 250155 [email protected] Mon–Thur: 08:30–17:00 | Fri: 08.30–16.00

1,600+ SkyAngel Skylight Covers for a Commercial Solar Project

Universal Safety Systems delivered over 1,600 SkyAngel rooflight protection covers for a commercial development ahead of solar panel installation. Completed within approximately one month, the project required protection for fragile rooflights that would retain natural daylight and support future rooftop maintenance.

The project demonstrates how planning skylight protection before solar installation can help manage fall-through hazards and coordinate protection with the wider construction programme.

Project Overview

Project overview
Project DetailSummary
Project ScaleOver 1,600 SkyAngel rooflight covers
ApplicationRooflight protection ahead of commercial solar panel installation
Main RequirementsFall-through protection, continued daylight transmission and protection for future maintenance
Installation ProgrammeApproximately one month
Delivery ApproachStaged deliveries coordinated with the installation programme

The challenge: rooflight protection around a planned solar installation

The development incorporated more than 1,600 rooflights across roof areas where photovoltaic arrays were due to be installed.

Rooflights provide valuable natural daylight, but fragile rooflights present a fall-through hazard during construction and maintenance. Brining solar installation teams onto the roof made it important to address this hazard before work began.

The project required a skylight protection system that could meet three practical needs:

  • Protect fragile rooflights during solar panel installation
  • Allow natural light to continue entering the building
  • Provide ongoing protection when teams returned for maintenance

With so many rooflights involved, the solution also needed to support a coordinated installation programme without creating unnecessary delivery or storage difficulties.

Why SkyAngel skylight protection covers were selected

SkyAngel creates a physical barrier above a fragile rooflight, providing fall-through protection while allowing daylight to pass through its open mesh construction.

For this deployment, the system combined rooflight protection with a low-profile design suited to a roof accommodating solar arrays. Its mesh construction retained the rooflights’ daylight function, while the cover system provided protection for subsequent maintenance activities.

These external skylight covers serve a safety purpose: they protect fragile rooflight areas rather than providing blackout or shading.

SkyAngel technical details
Technical Features
System Specification or
Characteristic
Project Benefit
Fall-through protectionPhysical barrier positioned above the fragile rooflightProtects the rooflight area during installation and future maintenance activities
Mesh constructionGalfan-coating steel meshProvides impact resistance and corrosion resistance for external use
Frame constructionRigid PVC-U frameSupports the protective mesh above the rooflight
Daylight transmissionOpen mesh design allows natural daylight to pass throughDetains the rooflights’ lighting function
ProfileLow-profile cover designSupports integration with the surrounding rooftop layout
Rooflight suitabilityConfigurations available for different rooflight dimensions and shapesAllows the system to be specified for the rooflights being protected

The cover configuration and installation requirements should follow the relevant SkyAngel instructions and project specification.

Coordinating more than 1,600 rooflight covers

At this scale, supplying the covers was only one part of the challenge. Materials needed to reach the installation teams in step with the programme.

USS coordinated staged deliveries to reduce on-site storage requirements while maintaining access to the covers needed for each installation phase. Production planning and technical support helped coordinate the order with the project timetable.

This approach connected supply, delivery and installation rather than treating them as separate activities.

Installation and quality checks The installation of over 1,600 rooflight covers was completed within approximately one month.

The programme combined installation sequencing with checks on cover positioning and secure fixing. USS worked with the project team to establish verification procedures across the installation, supporting consistency over a large number of rooflights.

Technical assistance remained available throughout the installation period. This helped the teams address installation requirements while maintaining progress.

Project outcomes

Project outcomes
OutcomeRecorded Project Result
Rooflight ProtectionOver 1,600 SkyAngel covers installed
Installation DurationApproximately one month
Delivery PerformanceDeliveries coordinated with the installation schedule
Product QualityNo defects reported across the supplied units
Continued Customer RelationshipA further order placed within weeks of completion

The completed installation provided protection ahead of the solar works while allowing daylight to continue entering the building.

The subsequent order provided further evidence of customer confidence in the solution and delivery process.

Solar panel skylight protection beyond installation

Roof access requirements continue after solar panels are installed. Inspections, cleaning, repairs and other maintenance can bring operatives back into proximity with fragile rooflights.

Planning solar panel skylight protection at the outset allows rooflight covers to be considered alongside the array layout and future access routes. It also helps avoid treating rooflight safety as a separate issue once the installation is complete.

For this project, the SkyAngel covers provided ongoing protection around the rooflights. Their continued performance depends on appropriate inspection, maintenance and use in accordance with the system requirements.

What this project demonstrates

The project highlights three considerations for facilities managers, contractors and building owners planning similar work.

Address rooflight hazards before solar work begins

Identify fragile rooflights early and include their protection in the rooftop work plan. This allows the protection strategy to be coordinated with the solar installation programme.

Consider daylight as well as protection

A rooflight protection solution should account for the rooflight’s function. Open mesh skylight covers provide a protective barrier while allowing natural light to reach the spaces below.

Plan for future maintenance access

Consider how people will reach and maintain the solar installation throughout its operational life. Rooflight protection should be assessed alongside access routes, roof edges and other hazards.

HSE guidance on fragile surfaces explains the need to avoid work on or near fragile surfaces where possible and control the remaining risks.

Questions about skylight and rooflight protection covers

What should you consider when choosing a skylight cover?

Consider the rooflight’s dimensions, shape and condition, the surrounding roof construction, and the work that will take place nearby. For solar projects, the proposed array layout and future maintenance routes should also inform the specification.

Can rooflight covers be used alongside solar panels?

Rooflight protection covers can form part of a roof safety strategy for buildings with solar installations. Their positioning should be coordinated with the solar equipment and access arrangements so the rooflights remain protected and maintenance routes are properly considered.

Are rooflight covers the same as roof walkways?

They have different functions. Rooflight covers provide protection over fragile rooflights, while walkways establish access routes across the roof. Do not assume a cove is a designated walking or working platform; follow the system’s approved use.

Do skylight protection covers remove the need for other fall protection?

Rooflight covers address the fall-through hazard at the protected rooflight. Roof edges, other fragile surfaces and access risks still need assessment. The wider safety solution may require guardrails, walkways or personal fall protection, depending on the work and roof layout.

Planning rooflight protection for a commercial solar project?

This project shows how more than 1,600 rooflights could be protected within a coordinated installation programme, with daylight and future maintenance requirements considered from the outset.

Explore SkyAngel skylight and rooflight protection covers or contact Universal Safety Systems to discuss your rooflight dimensions, roof construction and planned rooftop work.

Related Resources

Make an enquiry today